Back to old design!

MAGUS Bio VD300 Biological Inverted Digital Microscope

The price is valid only for the online store and may differ from the prices in retail stores.

With a camera and monitor. Magnification: 100–400x. Trinocular head, infinity plan achromatic objectives, 9W LED illuminator, condenser with a phase slider slot

Trinocular
The microscope head is a core element of the microscope that you look through to see a magnified sample
100 — 400
How much the size of a sample increases when you observe it through a microscope
Laboratory/medical
Application and use of the microscope
Availability

Product ID 83012
Brand MAGUS
Warranty 5 years
EAN 5905555018096
Package size (LxWxH) 64x42x67 cm
Shipping Weight 18.6 kg
Description

MAGUS Bio V300 is a biological microscope of an inverted design for studying samples in laboratory ware up to 70 mm high and with a bottom thickness up to 1.2 mm. The objects of study can be colonies of cells, tissue cultures, biological fluids, etc. The samples do not require mandatory pre-staining. The observations are made in transmitted light. Microscopy techniques: brightfield and phase contrast. The microscope is suitable for routine and research work, and teaching.

Digital camera

Video eyepiece with a SONY Exmor 8.3MP digital sensor. The sensor uses back-illumination technology to improve light sensitivity as well as to produce bright, clear images even in low light. The camera is used for work using the darkfield or brightfield microscopy technique on objectives with a magnification of 4x, 10x, and 20x. It also works with stereomicroscopes. A USB3.0 port with high data transfer speed (5Gbps) is used to connect to a computer and display images on the screen.

The MAGUS CDF30 camera is installed in the trinocular tube or in the eyepiece tube of a microscope. The maximum field of view without optical defects can be reached using an adapter with a magnification from 0.65x to 0.9x. To install it in the eyepiece tube, in addition to the adapter, you will also need an adapter matching the diameter of the tube.

The image is displayed on the computer screen with a maximum resolution of 3840x2160px. The frame rate is 45 fps. At a lower resolution (1920x1080px), the frame rate increases to 70fps. Transitions between frames are almost imperceptible, with no delays, and so the camera can be used to study and showcase moving objects. Photos and videos are recorded and saved in various formats.

Optics

The microscope is equipped with a classic trinocular head, the trinocular tube is used for mounting a digital camera. The camera is not included in the set. The beam splitting is 50/50.

Four included or additional objectives can be mounted in the revolving nosepiece. All objectives are designed to be used with laboratory ware and have a long working distance. There are 3 plan achromatic objectives for brightfield and 1 plan achromatic objective for the phase contrast technique.

Illumination

The transmitted light source is a 9W LED. The high power of the LED makes the illumination of the working area bright enough to work with all objectives and with any microscopy technique. The brightness adjustment does not change the color temperature. The LED lifetime is about 50,000 hours without LED replacement.

The condenser has a slot for a phase contrast slider (included). The phase contrast rings can be centered. The installation of the slider saves time when switching between the microscopy techniques.

Stage and focusing mechanism

Fixed mechanical stage. It is equipped with a dish holder (three dish holders of different sizes are included). The dishes can be moved along the X and Y axes by a mechanical attachment. The coaxial coarse and fine focusing mechanism provides accurate and fast focusing. The coarse focusing has a lock mechanism and tension adjustment.

Accessories

The optional accessories line includes phase objectives, eyepieces, digital cameras, and calibration slides.

Key features of the microscope:

  • Brightfield and phase contrast microscopy techniques in the transmitted light; studying samples in laboratory ware
  • Digital camera is mounted in the trinocular tube
  • 9W LED transmitted light illuminator with adjustable brightness and a long lifetime
  • Fixed stage with two-axis movement, 3 dish holders for different sizes included
  • Optional accessories to improve microscope performance

Key features of the camera:

  • SONY Exmor backlit color CMOS sensor, high light sensitivity
  • Operation in darkfield and brightfield using 4x, 10x, and 20x objectives
  • Computer connection via a USB3.0 interface with a data transfer speed of 5Gbps
  • Image output to a monitor in ultra-high resolution 4K 3840x2160px (45fps) or Full HD 1920x1080px (70fps)
  • Drivers and image processing software are included
  • Installation into the trinocular tube or the eyepiece tube of a microscope

The kit includes:

  • MAGUS CDF30 Digital Сamera (digital camera, USB cable, installation CD with drivers and software, user manual and warranty card)
  • Stand with the built-in power supply, transmitted light source, focusing mechanism, stage, condenser with a slot for phase-contrast slider, and revolving nosepiece
  • Trinocular head
  • Infinity plan achromatic objective: PL 10x/0.25 WD 4.27mm
  • Infinity plan achromatic objective: PL L20х/0.40 WD 8.0mm
  • Infinity plan achromatic objective: PL L40х/0.60 WD: 3.5mm
  • Infinity plan achromatic objective: PHP2 10x/0.25 phase WD 4.27mm
  • Eyepiece 10x/22mm with long eye relief (2 pcs.)
  • Eyecup (2 pcs.)
  • Centering telescope
  • Phase contrast slider with centering phase rings
  • Mechanical attachment for moving the specimen
  • Dish holder (3 pcs.)
  • C-mount camera adapter
  • Color filter
  • AC power cord
  • Dust cover
  • User manual and warranty card

Available on request:

  • 10x/22mm eyepiece with a scale
  • 12.5x/14mm eyepiece (2 pcs.)
  • 15x/15mm eyepiece (2 pcs.)
  • 20x/12mm eyepiece (2 pcs.)
  • 25x/9mm eyepiece (2 pcs.)
  • Infinity plan achromatic objective: PL 4x/0.10 WD 21mm
  • Infinity plan achromatic objective: PHP2 20x/0.40 phase WD 8.0mm
  • Infinity plan achromatic objective: PHP2 40x/0.60 phase WD 3.5mm
  • Calibration slide
  • LCD Monitor
Specifications
Product ID 83012
Brand MAGUS
Warranty 5 years
EAN 5905555018096
Package size (LxWxH) 64x42x67 cm
Shipping Weight 18.6 kg
Microscope specifications
Type biological, light/optical, digital
Head trinocular
Nozzle Siedentopf
Head inclination angle 45 °
Magnification, x 100 — 400
Magnification, x (optional) 40–500/600/800/1000
Eyepiece tube diameter, mm 30
Eyepieces 10х/22mm, eye relief: 10mm (*optional: 10x/22mm with scale, 12.5x/14; 15x/15; 20x/12; 25x/9)
Objectives infinity plan achromatic: PL 10x/0.25, PL 20x/0.40, PL 40x/0.60, PHP2 10x/0.25 phase; parfocal distance 45mm (*optional: PL 4x/0.10, PHP2 20x/0.40 phase, PHP2 40x/0.60 phase)
Revolving nosepiece for 4 objectives
Working distance, mm 4.27 (10x); 8.0 (20х); 3.5 (40x)
Interpupillary distance, mm 48 — 75
Stage moving range, mm 77/112
Stage features fixed, with mechanical attachment for moving the specimen; dish holders: 29x77mm, Ø90mm; 34x77.5mm, Ø68.5mm; 57x82mm, Ø60mm
Condenser NA 0.6, working distance: 70mm; with adjustable aperture diaphragm and a phase contrast slider slot
Diaphragm adjustable aperture
Focus coaxial, coarse (with coarse focusing tension adjustment and a lock knob), and fine (0.002mm)
Illumination LED
Brightness adjustment
Power supply 220±22V, 50Hz, AC network
Light source type 9W
Light filters yes
Operating temperature range, °C 5...+35
Special features phase contrast slider for a 10x objective with a centerable phase ring
User level experienced users, professionals
Assembly and installation difficulty level complicated
Application laboratory/medical
Illumination location lower
Research method bright field, phase-contrast microscopy
Pouch/case/bag in set dust cover
Camera specifications
Sensor SONY Exmor CMOS
Color/monochrome color
Megapixels 8.3
Maximum resolution, pix 3840x2160
Sensor size 1/1.2'' (11.14x6.26mm)
Pixel size, μm 2.9x2.9
Light sensitivity 5970mV/lux/s
Signal/noise ratio 0.13mV at 1/30s
Exposure time 0.02ms–15s
Video recording
Video recording yes
Frame rate, fps at resolution 45@3840x2160, 70@1920x1080
Place of installation trinocular tube, eyepiece tube instead of an eyepiece
Image format *.jpg, *.bmp, *.png, *.tif
Video format output: *.wmv, *.avi, *.h264 (Windows 8 and later), *h265 (Windows 10 and later)
Spectral range, nm 380–650 (built-in IR filter)
Shutter type ERS (electronic rolling shutter)
White balance manual, automatic
Exposure control manual, automatic
Software features image size, brightness, exposure time
Software MAGUS View
Output USB 3.0, 5Gb/s
System requirements Windows 8/10/11 (32bit and 64bit), Mac OS X, Linux, up to 2.8GHz Intel Core 2 or higher, minimum 2GB RAM, USB 3.0 port, CD-ROM, 17" or larger display
Mount type C-mount
Body solid aluminum
Camera power supply DC, 5V, from computer USB port; a 12V, 3A adapter for Peltier element
Camera operating temperature range, °С -10...+50
Operating humidity range, % 30 — 80
Video