Important information about prices and product availability. Learn more!
The price is valid only for the online store and may differ from the prices in retail stores.

True RMS. With DC current, inrush current, and power measurement. Functions: voltmeter, ammeter, ohmmeter, capacitance meter, frequency meter, duty cycle meter, wattmeter, thermocouple, continuity test, diode test, and NCV. Maximum jaw opening: 52mm

Ammeter, capacitance meter, duty cycle meter, frequency meter, ohmmeter, thermocouple, voltmeter
Basic functions of the measuring instrument
Cat. III (1000V), cat. IV (600V), pollution degree 2
Equipment overvoltage protection classification
5...+40
Operating temperature range: limit temperature values at which no additional errors occur in electrical measuring devices
Availability
Future arrivals
15 December 2026
20+

Product ID 87510
Brand Ermenrich
Warranty 5 years
EAN 5905555028774
Package size (LxWxH) 32x16x6 cm
Shipping Weight 0.88 kg
Description

The Ermenrich Zing DZ120 is a professional digital clamp meter with a built-in wattmeter. The device automatically calculates load power in AC and DC circuits, so you don’t need to separately measure current and voltage and then multiply them. The clamp meter is suitable for facility power engineers and electrical equipment commissioning and maintenance specialists. It can also be used for selective measurements during energy audits.

Current up to 1,500A and 52mm jaw opening

The jaws accommodate large-diameter cables, busbars, and bundles of parallel conductors. Both AC and DC current can be measured, which is important for solar installations, battery systems, and electric vehicles. Clamp only one phase or pole conductor at a time. The Inrush function captures short-term inrush current surges, for example, when diagnosing powerful electric motors and transformers.

Accuracy with distorted waveforms

Modern loads often draw non-sinusoidal current: This is how variable frequency drives, LED drivers, switching power supplies, and inverters operate. True RMS technology takes the waveform into account. Therefore, the current and power in such circuits are not underestimated. The built-in frequency meter up to 40MHz and duty cycle meter help to check the frequency at which the drive is operating at the moment of measurement.

Multimeter functions in one device

The capabilities of the Ermenrich Zing DZ120 cover the function set of most professional multimeters. With the thermocouple, the clamp meter measures temperature from −100°C to +1,000°C. You can check the heating of contacts and windings under load or the temperature in freezers. The device also measures capacitance up to 40mF, resistance up to 40MΩ, tests diodes with voltage up to 2.8V, and checks for open or short circuits.

Safety and kit

The device complies with CAT IV 600V and CAT III 1,000V overvoltage categories. The NCV indicator helps to pre-locate a phase but the absence of voltage before work must be confirmed by a contact measurement. The backlit display is easy to read in poorly lit rooms. Power is supplied by a single 9V battery (not included); the auto-off function preserves battery life during prolonged inactivity.

Key features:

  • Built-in wattmeter up to 900kW automatically calculates load power, saving time on manual calculations during energy audits
  • 52mm jaw opening and currents up to 1,500A allow testing main cables and busbars without shutting off power
  • Inrush function: captures inrush currents when starting electric motors and power equipment
  • True RMS technology guarantees accurate measurements in circuits with switching power supplies, inverters, and variable frequency drives
  • Thermocouple with measurement from −100°C to +1,000°C is suitable for monitoring cryogenic systems and red-hot furnaces or contacts under load
  • Capacitance (up to 40mF) and frequency (up to 40MHz) cover all needs for the in-depth diagnostics of PCBs, inverters, and digital circuits
  • NCV detector and CAT IV 600V/CAT III 1,000V ratings ensure safety when locating phases, working in electrical rooms and at the electrical installation's incoming point

The kit includes:

  • Digital clamp meter
  • Probe – 2 pcs.
  • Thermocouple
  • Pouch
  • User manual and warranty card
Specifications
Product ID 87510
Brand Ermenrich
Warranty 5 years
EAN 5905555028774
Package size (LxWxH) 32x16x6 cm
Shipping Weight 0.88 kg
Selection of the measuring limit automatic, manual
Basic functions ammeter, capacitance meter, duty cycle meter, frequency meter, ohmmeter, thermocouple, voltmeter
DC voltage measuring limit 400mV: accuracy ±(0.1%+5); 4V/40V/400V: accuracy ±(0.1%+4); 1,000V: accuracy ±(0.5%+4)
AC voltage measuring limit 400mV: accuracy ±(0.8%+40); 4V/40V/400V/750V: accuracy ±(1.0%+30)
DC current measuring limit 400A: accuracy ±(2.0%+30); 1,500A: accuracy ±(2.5%+30)
AC current measuring limit 400A: accuracy ±(2.8%+30); 1,500A: accuracy ±(2.5%+30)
Resistance measuring limit 400Ω: accuracy ±(0.5%+9); 4kΩ/40kΩ/400kΩ: accuracy ±(1.0%+4); 4MΩ: accuracy ±(2.0%+10); 40MΩ: accuracy ±(3.0%+10)
Capacity measuring limit 400nF: accuracy ±(3.5%+40); 4µF/40µF/400µF: accuracy ±(3.5%+10); 4mF/20mF: accuracy ±(5.0%+10); 40mF
Frequency measurement limits 40Hz/400Hz/4kHz/40kHz/400kHz/4MHz/40MHz: accuracy ±(0.3%+2)
DC power measurement limits 900kW: accuracy ±(3%+10)
AC power measurement limits 900kW: accuracy ±(2.8%+10)
Duty cycle measurement range 10%–95.0%: accuracy ±(1.0%+2)
Temperature measurement range –100°C...+1,000°C: accuracy ±(1.0%+2.5°C)
Wire mapping ✓
Continuity test +, threshold <50Ω, test current <0.5mA
Diodes test ✓
Diode test +, test current 0.3mA, open-circuit voltage 2.8V DC
Non-contact voltage detection (NCV) ✓
True RMS ✓
Hold function ✓
Limit value function (Min/Max) ✓
DCA Zero ✓
Inrush current measurement (INRUSH) ✓
Input impedance 10MΩ (DC and AC)
Throughput capacitance 50–400Hz (AAC/VAC)
Crest factor (peak factor) 3.0 on 40A and 400A ranges; 1.4 on 1,000A range (50/60Hz, 5%–100% of range)
Display yes
Display counts 4000
Display backlight ✓
Safety standards IEC1010-1 (2001); EN61010-1 (2001)
Overvoltage category cat. III (1000V), cat. IV (600V), pollution degree 2
Operating temperature range, °C 5...+40
Power supply 9V battery – 1 pc. (not included)
Auto power off ✓